Tu Es Belle CE Academy logo Tu Es Belle CE Academy

← Laser Hair Removal CE · Texas 8-Hour Renewal

Lesson 1 of 8 · 50 min

Laser Physics: How the Light Works

Meets TDLR's continuing education requirements under 16 TAC §118.25
Starting…

In this lesson

  • Light in plain words — wavelength, energy, and why the color of the light matters
  • Melanin — the target inside the hair, and why hair color and skin color change everything
  • Selective photothermolysis — the one idea every setting you choose rests on
  • The three dials you actually turn: fluence, pulse duration, and spot size
  • The device families: diode, alexandrite, Nd:YAG — and why IPL is not a laser
  • Cooling — how the skin's surface stays safe while the follicle heats up

Learning objectives

By the end of this lesson, you will be able to:

  • Explain wavelength and photon energy in plain language a client could understand
  • Name the skin's main chromophores and identify melanin as the target in laser hair removal
  • State the three conditions of selective photothermolysis
  • Describe what fluence, pulse duration, and spot size each control — and what happens when each is set wrong
  • Match each device family to the skin types it serves best, and explain why IPL is not a laser
  • Compare contact, cryogen, and air cooling, and explain why cooling is a safety setting, not a comfort extra

---

Welcome

Welcome to your renewal course, and welcome to Lesson 1.

Before we touch a protocol, a consent form, or a treatment room, we start where every safe treatment starts: with the light itself.

You already hold a Texas laser hair removal certificate. You already know your device. This lesson is the refresher underneath all of that — why the light does what it does, in plain words, so that every setting you choose for the rest of this course is a decision you understand, not a number you memorized.

Here is the promise of this lesson: by the end, the three dials on your device will not be settings. They will be answers to three questions you can say out loud.

Let's begin with the light.

---

Light, in plain words

A laser is a light source. That sounds too simple to matter — it matters completely.

Ordinary light spreads out. A lamp or a flashlight throws light in every direction, in many colors at once, and it weakens quickly with distance.

Laser light is organized. A laser produces light that is:

  • One wavelength — a single, precise color (this is called monochromatic)
  • In step — the waves travel together, crest to crest (coherent)
  • In one direction — a tight, focused beam that barely spreads (collimated)

That organization is what lets a laser deliver a large amount of energy to a very small target — a hair follicle — without treating the whole skin surface the same way.

Wavelength: the color you cannot always see

Light travels in waves. The distance from one wave's crest to the next is its wavelength, measured in nanometers (nm).

  • Short wavelengths sit at the violet and blue end of the spectrum.
  • Long wavelengths run through red into infrared — beyond what the eye can see.
  • Laser hair removal devices work in the red and near-infrared range, roughly 690 to 1,100 nm — at and past the edge of visible light.

Energy: the part that does the work

Light carries energy in tiny packets called photons. When a photon is absorbed by tissue, its energy converts to heat.

  • Shorter wavelength = more energy per photon, but it is absorbed near the surface.
  • Longer wavelength = less energy per photon, but it travels deeper before it is absorbed.

For hair removal, we need light that reaches down to the follicle — the bulb and bulge sit roughly 2 to 5 millimeters below the surface, depending on the body area — and gives its energy up there, not on the surface.

That balance — deep enough to reach the follicle, absorbed strongly enough to heat it — is the whole physics of this course in one sentence.

The optical window: why our wavelengths live where they do

The red and near-infrared band, roughly 690 to 1,100 nm, is sometimes called the optical window of skin. It earned the name:

  • Shorter than ~690 nm — melanin and hemoglobin absorb so strongly that the light spends itself at the surface. Plenty of heat, none of it deep.
  • Inside the window — absorption is moderate and falls steadily as wavelength rises, while penetration deepens. Light can reach the follicle with energy left to give.
  • Longer than ~1,100 nm — melanin absorbs too weakly to heat the follicle well, and water begins to take over as the absorbing chromophore. That is a different treatment entirely.

Every LHR device you will ever use sits inside this window. The three laser families in Section 7 are simply three chosen points along it — and where a device sits in the window predicts almost everything about how it behaves.

---

The target: melanin

Light only heats what absorbs it. A substance in the skin that absorbs light is called a chromophore. Skin has three that matter to us:

  • Melanin — the pigment in hair and skin. This is our target.
  • Hemoglobin — the pigment in blood. It absorbs shorter wavelengths strongly.
  • Water — the main content of skin cells. It absorbs the far-infrared wavelengths used by resurfacing lasers — not hair removal devices.
✦Melanin · the targetThe pigment in hair and skin. This is our target.
✦Hemoglobin · in bloodThe pigment in blood. It absorbs shorter wavelengths strongly.
✦Water · in every cellThe main content of skin cells. It absorbs the far-infrared wavelengths used by resurfacing lasers — not hair removal devices.

Why melanin is the perfect target — and the permanent problem

The hair shaft and follicle carry far more melanin than the skin around them — in light skin with dark hair. The laser's job is to be absorbed by that melanin, turn to heat inside the follicle, and damage the follicle's growth structures so the hair does not grow back.

But melanin is also in the epidermis — the skin's surface layer — and the amount rises with skin type and with tanning.

How deep is the target?

The follicle is not at one standard depth. Its bulb and bulge sit:

  • Shallower on the face — roughly 1.5 to 3 mm, varying with the area and the hair's thickness
  • Deeper on the body — roughly 3 to 5 mm on areas like the legs and bikini line

Depth is not trivia. It is why the same settings behave differently on the upper lip and the shin, why spot size (Section 6) matters more on the body than the face, and why a coarse, deep follicle needs its heat delivered differently than a fine, shallow one. When Lesson 4 sets parameters by body area, this is the physics it is applying.

So every LHR treatment is a controlled competition:

  • Follicle melanin — you want it to absorb, heat, and be damaged.
  • Epidermal melanin — you want it to absorb as little as possible.

Everything in this course — wavelength choice, fluence, pulse duration, cooling, test spots, "not today" decisions — is a way of winning that competition for the follicle and protecting the epidermis.

Two melanins — why red hair is its own case

Melanin comes in two forms, and the difference is pure physics:

  • Eumelanin — brown to black pigment. Absorbs red and near-infrared light strongly. This is the working target in dark hair.
  • Pheomelanin — red to yellow pigment, dominant in red hair. Absorbs our wavelengths weakly.

A red-haired client's follicles are not pigment-free — they hold the wrong kind of pigment for these wavelengths. Expect weak response even at correct settings, and say so at consultation rather than after six sessions.

Hair color decides whether the target exists

  • Black and dark brown hair — rich in melanin. The strongest target. Best response.
  • Light brown and dark blond hair — moderate melanin. Response varies; expectations must be set honestly.
  • Blond, red, gray, and white hair — little or no melanin in the follicle. There is effectively no target. Laser light passes through without heating the follicle.

---

Selective photothermolysis — the one big idea

In 1983, researchers R. Rox Anderson and John Parrish published the principle that all of laser hair removal is built on: selective photothermolysis.

Broken into its parts: photo = light · thermo = heat · lysis = destruction · selective = only the chosen target.

In plain words: choose the right light, deliver it in the right amount of time, and you can destroy a tiny target inside the skin while the tissue around it stays unharmed.

It works when three conditions are met at the same time:

  1. A wavelength the target absorbs far more strongly than the surrounding tissue.
  2. Enough energy to heat the target to the point of damage.
  3. A pulse short enough that the heat stays in the target instead of spreading into the skin around it.

Miss any one of the three, and the treatment fails in a predictable direction:

  • Wrong wavelength → the wrong tissue absorbs, or nothing does.
  • Too little energy → the follicle warms but recovers. Hair returns.
  • Pulse too long → heat leaks outward during the pulse. The surface burns while the follicle survives.
3. Selective photothermolysis — the one big idea

Three-panel emerald diagram — (1) light enters skin, (2) energy absorbs in the dark follicle, (3) follicle heats and is disabled while the surface stays cool. Each panel captioned in one short line; the narration reads the same three steps aloud.

What "damage" means in degrees

Heat damages tissue by denaturing protein — the same change that turns egg white from clear to white. For the follicle's growth structures, that change begins at roughly 65 °C (about 150 °F) held for a brief moment. The treatment goal is precise: push the follicle past that threshold while the epidermis stays far below it.

Two refinements complete the picture:

  • The real target is bigger than the hair shaft. The structures that must be disabled — the bulge and the bulb — sit beside and below the pigmented shaft and carry less melanin themselves. Heat must conduct outward from the shaft into them. Physicists call the time that takes the thermal damage time, and it is longer than the shaft's own relaxation time — one reason modern LHR pulses run longer than the earliest theory suggested.
  • Damage is temperature × time. A slightly lower temperature held longer can equal a higher temperature held briefly. Pulse duration, Section 5, is how you spend that trade.

Keep this picture in your mind. The next three sections are simply the three dials that control it.

---

Dial one: fluence — how much energy

Fluence is the energy delivered per unit of area, measured in joules per square centimeter (J/cm²).

Think of it as the strength of each pulse:

  • Too low — the follicle is warmed, not damaged. The client completes a full series and keeps most of the hair. Undertreatment is the quiet failure of this field.
  • In range — the follicle reaches the temperature that disables its growth structures.
  • Too high — the epidermis absorbs more than it can shed. Burns, blisters, and pigment change follow — the subject of Lesson 5.

Fluence is not a bravery contest and it is not a fixed number per device. The right fluence for a client depends on skin type, hair color and thickness, body area, and the device's wavelength and spot size. That is why Lesson 4 builds settings from the client in front of you — never from the last client's chart.

Fluence, spot size, and the pulse's total energy

Fluence is energy per area — so the pulse's total energy also depends on the spot it lands on:

  • Total energy (J) = fluence (J/cm²) × spot area (cm²)
  • Double the spot's diameter and the same fluence delivers roughly four times the total energy — one reason a large-spot handpiece feels "stronger" at identical settings.

This is also why a fluence copied from another device, another handpiece, or another practitioner's chart is not a setting — it is a guess. Fluence only means something together with the wavelength, spot size, and pulse duration it was chosen for.

One dial, two chairs. Picture the same fluence leaving the screen in two different rooms. In the first, it lands through a large spot on a pale leg with coarse black hair: scatter losses are low, the follicle's melanin is dense, and the surface above it holds little pigment to compete. In the second, the identical number lands through a small spot on tanned skin over fine hair: more light is lost to scatter, the epidermis takes a larger share, and the follicle offers far less target. Same number — two different treatments. The dial never travels alone; it always arrives with the client attached.

---

Dial two: pulse duration — how fast the energy lands

Pulse duration (also called pulse width) is how long each pulse lasts, measured in milliseconds (ms).

The same energy can arrive as a short, sharp pulse or a longer, gentler one. The target's size decides which is right, through a principle called thermal relaxation time — the time a heated structure takes to lose half its heat to the tissue around it.

  • Small structures cool fast. The epidermis — a thin sheet — sheds heat in roughly 3 to 10 milliseconds.
  • Large structures cool slowly. A hair follicle holds its heat for roughly 20 to 100 milliseconds, depending on its diameter.
StructureApproximate sizeThermal relaxation time
Epidermis~0.1 mm sheet~3–10 ms
Hair shaft / follicle~0.2–0.3 mm across~20–100 ms
Small blood vessel~0.05 mm~1–5 ms

Read the table as a race: after a pulse lands, every heated structure starts leaking heat. The small ones finish leaking quickly; the follicle is still holding most of its heat long after the surface has cooled.

Now the logic of pulse duration falls into place:

  • Set the pulse longer than the epidermis's relaxation time → the surface can shed heat during the pulse and survives.
  • Set it shorter than the follicle's relaxation time → the follicle cannot shed heat fast enough. Heat stays trapped inside it. The follicle is damaged.

That is the window every LHR pulse aims for: long enough to spare the surface, short enough to trap the heat in the follicle.

Practical consequences you will use:

  • Finer hair holds less heat → shorter pulses.
  • Coarser hair holds more heat → longer pulses still trap it.
  • Darker skin carries more epidermal melanin → longer pulses give the surface more time to shed heat safely.

One more timing term: repetition rate

Repetition rate, measured in hertz (Hz), is how many pulses fire per second while you glide or stamp the handpiece. It is a speed setting, not a dose setting — but it has a physics consequence: pulses delivered to the same spot in quick succession stack their heat, because the tissue has no time to cool between them.

  • Stamping technique — one pulse per placement, deliberate overlap. Heat stacking is minimal and controlled.
  • Gliding ("in-motion") technique — many low-fluence pulses over a moving area, building temperature gradually. Safe only when the motion never stalls: a paused handpiece stacks full heat in one place.

However you deliver them, the tissue only knows the total heat history. Respect it.

Which setting does what

Three sliders labeled Fluence / Pulse duration / Spot size. Moving each slider shows one line: what rises, what falls, and what goes wrong at each extreme.

Too low — the follicle is warmed, not damaged. The client completes a full series and keeps most of the hair.

Fluence is the energy delivered per unit of area, measured in joules per square centimeter (J/cm²). Think of it as the strength of each pulse.

Too low: the follicle is warmed, not damaged — undertreatment is the quiet failure of this field. Too high — the epidermis absorbs more than it can shed. Burns, blisters, and pigment change follow.

Set it shorter than the follicle's relaxation time → the follicle cannot shed heat fast enough. Heat stays trapped inside it. The follicle is damaged. Finer hair holds less heat → shorter pulses.

Set the pulse longer than the epidermis's relaxation time → the surface can shed heat during the pulse and survives. Darker skin carries more epidermal melanin → longer pulses give the surface more time to shed heat safely; coarser hair holds more heat → longer pulses still trap it.

Pulse too long → heat leaks outward during the pulse. The surface burns while the follicle survives. The window every LHR pulse aims for: long enough to spare the surface, short enough to trap the heat in the follicle.

Smaller spot → more scatter loss, shallower effect, useful for small or curved areas like the upper lip.

Larger spot → deeper effective penetration, faster coverage of large areas — and, at the same fluence, more energy reaching the follicle, so settings are not interchangeable between handpieces.

Changing handpieces changes the treatment even at identical numbers on the screen. Spot size is a dose setting, not an accessory. In a narrow beam, much of the light scatters out the sides and is lost before it reaches follicle depth.

---

Dial three: spot size — how wide the beam lands

Spot size is the diameter of the beam where it meets the skin, measured in millimeters (mm) — commonly 12 to 24 mm on modern handpieces.

Spot size changes depth, not just coverage. Here is why: light scatters as it enters skin. In a narrow beam, much of the light scatters out the sides and is lost before it reaches follicle depth. In a wide beam, the light scattered from one part is replaced by light scattered in from beside it — so more energy survives to reach the deeper follicles.

  • Larger spot → deeper effective penetration, faster coverage of large areas — and, at the same fluence, more energy reaching the follicle, so settings are not interchangeable between handpieces.
  • Smaller spot → more scatter loss, shallower effect, useful for small or curved areas like the upper lip.

---

The device families — and the one that is not a laser

Every LHR device is a way of producing one chosen wavelength. Four names cover the field.

Alexandrite — 755 nm

  • Strongly absorbed by melanin. Excellent for lighter skin types (Fitzpatrick I–III) with dark hair.
  • The strong melanin absorption that makes it effective also makes it risky on darker or tanned skin — the epidermis competes too well.
  • Fast repetition rates make it a workhorse for large areas on suitable skin.

Diode — 800 to 810 nm

  • The most widely used family in the field. A step deeper and a step gentler on melanin than alexandrite.
  • Serves light to medium skin types (I–IV) well; many platforms add contact cooling in the handpiece tip.
  • Versatile, durable, and the platform most practitioners in this course will know best.

Nd:YAG — 1,064 nm

  • The longest wavelength of the three true lasers here. Melanin absorbs it least — and that is its strength.
  • Because the epidermis absorbs so little, it is the safest choice for darker skin types (IV–VI) and for tanned skin when treatment is appropriate at all.
  • It reaches deep. Weaker melanin absorption can mean more sessions for fine hair — an honest trade-off to explain at consultation.

IPL — not a laser

Intense pulsed light (IPL) is a flashlamp, not a laser. It fires a band of many wavelengths at once, shaped by filters, rather than one coherent wavelength.

  • It can reduce hair on suitable candidates, and it has legitimate uses.
  • But it is less selective: more wavelengths mean more absorption by tissue you did not target.
  • It must never be described to a client as "laser." As physics, the words are not interchangeable — one exact wavelength versus a filtered band of many. But know how Texas law treats it: the Texas rules define laser hair removal as the use of "a laser or pulsed light device" (§118.10(15)), so pulsed-light hair removal sits inside the same Texas LHR rules as laser treatment — same certificate, same facility rules. The distinction that matters in Texas is honesty: call the device what it is.
7. The device families — and the one that is not a laser

The wavelength spectrum as a gold band on ivory — visible light on the left, infrared on the right, with the three laser wavelengths marked as sharp emerald lines (755 · 810 · 1,064) and IPL drawn as a wide soft band. Tapping each marker shows the device's one-line profile; the narration reads the same profiles.

The four families, side by side

DeviceWavelengthMelanin absorptionServes bestWatch out for
Alexandrite755 nmHighestFitzpatrick I–III, dark hairEpidermal competition on darker or tanned skin
Diode800–810 nmModerateFitzpatrick I–IVSettings vary widely between platforms
Nd:YAG1,064 nmLowestFitzpatrick IV–VIWeaker response on fine hair; may need more sessions
IPL (not a laser)Broad band, filteredMixed, less selectiveSuitable light-skin candidatesMust never be called "laser"

Settings do not travel

Notice what the table cannot give you: numbers. A fluence and pulse duration that are perfect on a diode platform with an 18 mm spot say nothing about the same numbers on an alexandrite with a 15 mm spot and cryogen cooling. Wavelength changes absorption, spot size changes depth and total energy, and cooling changes the surface budget — all at once.

The transferable skill is not a chart of numbers. It is the reasoning in this lesson: target, dose, timing, depth, protection. Numbers belong to a device, a client, and a day — in that order. Lesson 4 builds them that way.

Hair and skin matcher

Tap-to-change pair — choose a hair color (black / brown / blond / gray) and a skin tone (Fitzpatrick I through VI) and see the guidance change: which device family fits, what the physics warns about, and when the honest answer is that laser will not work on that hair.

Rich in melanin. The strongest target. Best response. Alexandrite (755 nm): strongly absorbed by melanin, excellent for lighter skin types (Fitzpatrick I-III) with dark hair; diode also serves this picture — the classic candidate, the epidermis competes least here.
Diode (800 to 810 nm) serves light to medium skin types (I-IV) well; many platforms add contact cooling in the handpiece tip.
Diode territory; longer pulses give the epidermis time to shed heat. Type the tan state carefully — this band tans, and tans move clients.
Nd:YAG (1,064 nm) — because the epidermis absorbs so little, it is the safest choice for darker skin types (IV-VI). Weaker melanin absorption can mean more sessions for fine hair.
Nd:YAG (1,064 nm) — the epidermis absorbs least at this wavelength. Alexandrite is the wrong answer here.
Alexandrite: the strong melanin absorption that makes it effective also makes it risky on darker or tanned skin — the epidermis competes too well. Nd:YAG is the safest choice for tanned skin when treatment is appropriate at all.
Moderate melanin. Response varies; expectations must be set honestly.
Pheomelanin — red to yellow pigment, dominant in red hair — absorbs our wavelengths weakly. Expect weak response even at correct settings, and say so at consultation rather than after six sessions.
Little or no melanin in the follicle. There is effectively no target. Laser light passes through without heating the follicle. No setting fixes a missing target. Turning up the energy on gray or white hair does not create melanin — it only heats the skin.
IPL (not a laser): a broad band, filtered; mixed, less selective absorption. It must never be called “laser.”

---

Cooling — protecting the surface while the follicle cooks

Section 3 gave the follicle a problem: it must reach damaging temperature. Section 1 gave the epidermis the opposite need: it sits above the follicle, and every pulse passes through it first.

Cooling is how we resolve that. Its job is to pull heat out of the epidermis before, during, and after the pulse — while the deeper follicle, too deep for the cooling to reach in time, keeps its heat.

Three methods dominate:

  • Contact cooling — a chilled tip or window in the handpiece touches the skin. Cools before, during, and after the pulse. Firm, even contact matters — a lifted edge is an uncooled edge.
  • Cryogen spray cooling — a measured burst of refrigerant sprays the skin a fraction of a second before (and sometimes after) the pulse. Precise and fast; the spray timing is part of the dose.
  • Forced air cooling — a stream of very cold air over the treatment area, before and during treatment. Flexible, and the client feels it working.

What cooling is not:

  • It is not a comfort feature you can skip on a "tough" client. It is part of the safety calculation that the fluence was chosen under.
  • It does not license higher fluence. Cooling widens the safety margin; spending the whole margin on more energy gives it back.
  • It does not fix a wrong wavelength or a tanned-skin treatment that should have been postponed.

Cooling has limits — know them

Cooling works by conduction and contact at the surface, and physics gives it a shallow reach: in the time around a pulse, cooling meaningfully protects roughly the top millimeter of skin. That is exactly the epidermis — and nowhere near the follicle bulb at 2 to 5 mm down. This is not a flaw; it is the design. Cooling is selective in depth the way the wavelength is selective in target.

Timing matters too:

  • Pre-cooling lowers the surface's starting temperature, buying headroom for the pulse.
  • Parallel cooling (contact during the pulse) extracts heat while energy lands.
  • Post-cooling shortens the time the surface spends hot afterward — when much surface injury is decided.

A device that cools only afterward is offering one of the three protections. Know which yours provides.

✦CoolingCooling protects the surface. It never raises the ceiling.

---

Three mistakes, read through physics

Before we put it together, read the three classic failures with this lesson's eyes:

  • "The series finished and the hair is all still there." The follicle never reached damaging temperature — fluence too low for that hair and skin, a wavelength absorbed too weakly, or pulses so long the follicle shed heat as fast as it arrived. A dose problem.
  • "The client blistered in a neat row of rectangles." The surface took more than it could shed — fluence too high for that epidermis, cooling skipped or uneven, or pulses stacked on one spot. A surface-budget problem.
  • "It worked beautifully on her legs and did nothing on her upper lip." Fine, lighter lip hair holds less melanin and less heat than coarse leg hair — different target, different dose and timing. A target problem.

Every troubleshooting conversation in this field resolves into one of those three. The rest of this course teaches you to see them coming at consultation, not after.

Pause and practice: the leg and the lip

One client, Fitzpatrick type III. Two treatment areas: lower legs — coarse, black hair — and upper lip — fine, pale-blond hair. Your platform is a diode. Decide each point before reading its answer.

Decision 1 — Which area is the strong laser candidate? The legs. Coarse black hair is dense eumelanin in a thick shaft: a strong absorber that also holds its heat (the long end of the relaxation range). The lip hair is the opposite case — fine, and pale blond, so its melanin is sparse. Same client, same device, two completely different targets.

Decision 2 — The leg settings are dialed in. She asks for the lip "at the same settings, while we're here." Do the numbers transfer? No. The lip follicle is shallower and finer, so it sheds heat faster — timing that traps heat in a coarse leg follicle is not the timing a fine follicle calls for. And dose follows the target: a weak absorber does not become strong because the fluence was borrowed from a stronger one. Settings are chosen per area, per hair — never carried across the body on one chart line.

Decision 3 — She suggests turning the fluence up on the lip to "make it work." Your answer? More fluence cannot manufacture a target. On pale-blond hair, extra energy mostly heats the epidermis — the dose problem from the mistakes above, created on purpose. The professional answer is the honest one from Section 2: explain now that lip response will be weak at any safe setting, and let her decide with the truth in hand.

Putting it all together — one treatment, in physics

Watch the whole lesson fire in a single pulse:

  1. You selected the wavelength your device produces — chosen, through the device itself, for this client's skin type and hair color.
  2. The light enters the skin. The epidermis absorbs some — cooling is already pulling that heat away.
  3. The surviving light reaches the follicle, where dense melanin absorbs it strongly and turns it to heat.
  4. The fluence was enough to raise the follicle to damaging temperature.
  5. The pulse duration sat in the window — too fast for the follicle to shed its heat, slow enough for the surface to shed its own.
  6. The spot size carried enough of the beam past the scatter to follicle depth.

Six ideas. One pulse. That is selective photothermolysis — and it is the foundation under every protocol, reaction, and safety rule in the seven lessons ahead.

---

Key points

  • Laser light is organized light: one wavelength, in step, in one direction — which is why it can deliver serious energy to a tiny target.
  • Melanin is the target. The follicle's melanin must absorb and heat; the epidermis's melanin must be protected. Every setting arbitrates between them.
  • Selective photothermolysis needs three things at once: a wavelength the target absorbs, enough energy, and a pulse short enough to trap the heat in the target.
  • Fluence is dose (J/cm²): too low undertreats, too high burns. Pulse duration exploits thermal relaxation time — the surface sheds heat in ~3–10 ms, the follicle holds it for ~20–100 ms. Spot size controls depth through scatter: wider reaches deeper.
  • Alexandrite 755 for lighter skin, diode 810 the versatile middle, Nd:YAG 1,064 safest for darker skin — and IPL is not a laser.
  • Hair without melanin — gray, white, blond, red — has no target. No setting changes that.
  • Cooling protects the epidermis before, during, and after the pulse. It is a safety setting, never a license to raise fluence.

---

Next lesson: Lesson 2 — Device Safety & Using the LHR Device: the controlled area, pre-treatment checks, and the rules that govern who may fire the device, and how.

🎧 Laser Physics: How the Light Works — audio version
Press play to listen to this lesson.
Audio is generated on your device — no downloads needed. Listening counts the same as reading toward your lesson time.

Watch & Listen — the full lesson

Press play and the narration runs with an animated visual track that follows the lesson from the first minute to the last — watch and listen together. Pause any time, or tap the gold bar to jump; the pictures always match the voice.

Loading the visual track…

0:00

The Read tab carries this same lesson in full — the moving pictures follow the narration; they never replace the text.

One pulse, slowed down

An animated explainer plays a single pulse in slow motion: the beam crosses the epidermis while cooling pulls heat from the surface, the follicle absorbs and climbs past the damage threshold, and the surrounding skin stays below it. The narration from Sections 1-3 plays over it.

epidermis follicle
Follicle temperature
damage threshold ≈ 65 °C
Surface temperature
cooling holds it down
The pulse begins
The follicle heats
The surface stays safe

Watching counts the same as reading or listening toward your lesson time.

Lesson materials